Split Glands (PGS)
Sealing Glands
> Single Element Probe / Tube Sealing >
For Large Diameter Ends >

Example: PG2S-093-A-T
Multimedia: View Video of this Product![]()
Features:
- Seals 1 Element
- For Gas or Liquid
- Stainless Steel Fitting
- Simple Assembly - Insert Element, Torque Cap
- Replaceable Sealant Permits Repeated Use Of Fitting
- Field Adjustable
- Tube Stress Concentration Minimized
- Temperature Range From -400°F to +1600°F (-185°C to +870°C)
- Pressure*: Vacuum to 10,000 PSI (690 bar)
Application Ideas:
- Sealing of analyzer sampling probes with blow-out collars; allows probe change out with removal of gland body.
- Gas filled capillary bulb temperatue sensors (PartLow style).
- Cable assemblies with factory installed connectors (vibration sensors).
- Sealing of a simple long length conductor, simplifying assembly, disassembly and change out of sealant.
Replacement Sealant (RS) consisting of sealant only is also available.
Example: RS-PG2S-093-T